Cardiac Surgery

SP-GRIPFLOW™

 

sp-gripflow
uni

SP-GRIPFLOW™, Excellent Materials and Stable Manipulation A balloon with a grid-like ribbed surface can minimize slippage.

During surgery for aortic arch aneurysm and dissecting aortic aneurysm, antegrade blood flow (perfusion) can be demonstrated for cerebroprotection through these catheters inserted into three branches of the aorta.

 

Device Details

sp-gripflow

Specifications TypeⅠ Ordering Information

Reference No. O.D.(mm) Effective Length(mm) Total Length(mm)
1182212 4.0(12Fr) 270 361
1182214 4.7(14Fr)
1182216 5.3(16Fr)

Specifications TypeⅡ Ordering Information

Reference No. O.D.(mm) Effective Length(mm) Total Length(mm)
1182312 4.0(12Fr) 270 443
1182314 4.7(14Fr)
1182316 5.3(16Fr)

Thailand, Taiwan, UAE

sp-gripflow
uni

SP-GRIPFLOW™, Excellent Materials and Stable Manipulation A balloon with a grid-like ribbed surface can minimize slippage.

During surgery for aortic arch aneurysm and dissecting aortic aneurysm, antegrade blood flow (perfusion) can be demonstrated for cerebroprotection through these catheters inserted into three branches of the aorta.

 

Features

uni
  • Silicone rubber selected for medical application can reduce trauma to the tunica intima.
  • The catheter comes with a stylet with a luer-lock connector to maintain its shape during perfusion (for Type I, only).
  • Perfusion pressure monitoring can be performed at the catheter tip.
  • Blood flow during perfusion can be visually confirmed.
  • The catheter is provided with depth markings on the distal tip for insertion depth reading.

Device Details

sp-gripflow

Specifications TypeⅠ Ordering Information

Reference No. O.D.(mm) Effective Length(mm) Total Length(mm)
1181708 2.7(8Fr) 270 361
1181710 3.3(10Fr)
1181712 4.0(12Fr)
1181714 4.7(14Fr)
1181716 5.3(16Fr)

Specifications TypeⅡ Ordering Information

Reference No. O.D.(mm) Effective Length(mm) Total Length(mm)
1181808 2.7(8Fr) 270 410
1181810 3.3(10Fr)
1181812 4.0(12Fr)
1181814 4.7(14Fr)
1181816 5.3(16Fr)

 

Vietnam, India, Brazil

sp-gripflow
uni

SP-GRIPFLOW™, Excellent Materials and Stable Manipulation A balloon with a grid-like ribbed surface can minimize slippage.

During surgery for aortic arch aneurysm and dissecting aortic aneurysm, antegrade blood flow (perfusion) can be demonstrated for cerebroprotection through these catheters inserted into three branches of the aorta.

 

Device Details

sp-gripflow

Specifications TypeⅠ Ordering Information

Reference No. O.D.(mm) Effective Length(mm) Total Length(mm)
1183212 4.0(12Fr) 270 361
1183214 4.7(14Fr)
1183216 5.3(16Fr)

Specifications TypeⅡ Ordering Information

Reference No. O.D.(mm) Effective Length(mm) Total Length(mm)
1183312 4.0(12Fr) 270 443
1183314 4.7(14Fr)
1183316 5.3(16Fr)